EKBS-20 Aeration Kit Battery Installation Instructions
STOP:
FIRST:
CONNECT RED BATTERY CLIPS TO POSTIVE + POST ON  BATTERIES.

NEXT:
CONNECT BLACK BATTERY CLIPS TO NEGATIVE - POST ON BATTERY. 
When connecting batteries together to form larger "banks" (a battery of batteries?), the constituent batteries must be matched to each other so as to not cause problems.

We know that the current is equal at all points in a series circuit, so whatever amount of current there is in any one of the series-connected batteries must be the same for all the others as well. For this reason, each battery must have the same amp-hour rating, or else some of the batteries will become depleted sooner than others, compromising the capacity of the whole bank. You will be connecting 2 batteries in parallel for greater current capacity (lower internal resistance), or greater amp-hour capacity:

We know that the voltage is equal across all branches of a parallel circuit, so we must be sure that these batteries are of equal voltage. If not, we will have relatively large currents circulating from one battery through another, the higher-voltage batteries overpowering the lower-voltage batteries. This is not good.

With a parallel battery bank, one fuse is adequate for protecting the wiring against load overcurrent (between the parallel-connected batteries and the load), but we have other concerns to protect against as well. Batteries have been known to internally short-circuit, due to electrode separator failure, causing a problem not unlike that where batteries of unequal voltage are connected in parallel: the good batteries will overpower the failed (lower voltage) battery, causing relatively large currents within the batteries connecting wires.
EKBS-20 HOME PAGE